{"id":917,"date":"2026-03-23T08:48:16","date_gmt":"2026-03-23T08:48:16","guid":{"rendered":"https:\/\/zdmflooring.com\/?p=917"},"modified":"2026-03-23T08:48:16","modified_gmt":"2026-03-23T08:48:16","slug":"steel-fiber-reinforced-concrete-vs-rebar","status":"publish","type":"post","link":"https:\/\/zdmflooring.com\/es\/steel-fiber-reinforced-concrete-vs-rebar\/","title":{"rendered":"Fibra de acero frente a armadura tradicional: \u00bfcu\u00e1l es m\u00e1s rentable?"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>Why Does Traditional Reinforced Concrete Flooring Crack?<\/strong><\/h2>\n\n\n\n<p>When designing high-performance industrial floors, the debate of <strong>Steel Fiber Reinforced Concrete vs Rebar<\/strong> is crucial for ensuring long-term durability. While traditional mesh has been the standard, <strong>Hormig\u00f3n reforzado con fibra de acero (SFRC)<\/strong> is now the superior choice to enhance tensile strength and prevent surface cracking in modern construction.<\/p>\n\n\n\n<p>In traditional concrete flooring, <strong>steel reinforcement mesh is distributed in a two-dimensional (2D) plane<\/strong>, which cannot provide effective three-dimensional restraint within the concrete structure.<\/p>\n\n\n\n<p>As a result, two major problems occur:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The upper layer of plain concrete is prone to <strong>surface peeling and spalling<\/strong><\/li>\n\n\n\n<li>Once cracks form inside the concrete, they easily <strong>propagate to the surface<\/strong> due to the lack of multi-directional reinforcement<\/li>\n<\/ul>\n\n\n\n<p>This limitation makes conventional reinforced concrete floors vulnerable to cracking, especially in <strong>industrial and heavy-load environments<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>How Steel Fiber Concrete Solves Cracking Problems<\/strong><\/h2>\n\n\n\n<p><strong>Steel fiber reinforced concrete (SFRC)<\/strong> replaces traditional rebar mesh with a <strong>three-dimensional (3D) reinforcement system<\/strong>.<\/p>\n\n\n\n<p>Instead of a flat reinforcement layer, steel fibers are <strong>evenly distributed throughout the entire concrete matrix<\/strong>, forming a spatial support structure.<\/p>\n\n\n\n<p>This provides:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Full-directional restraint against internal stress<\/li>\n\n\n\n<li>Improved tensile strength and crack resistance<\/li>\n\n\n\n<li>Better load distribution<\/li>\n<\/ul>\n\n\n\n<p>As a result:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Surface layer peeling is significantly reduced<\/li>\n\n\n\n<li>Internal cracks are effectively controlled and prevented from expanding<\/li>\n<\/ul>\n\n\n\n<p>\ud83d\udc49 En t\u00e9rminos sencillos:<br><strong>Steel fibers make cracks \u201chave nowhere to go.\u201d<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-1024x683.png\" alt=\"Steel Fiber Reinforced Concrete vs Rebar Mixing process of steel fiber reinforced concrete for industrial flooring\" class=\"wp-image-918\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-1024x683.png 1024w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-300x200.png 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-768x512.png 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-18x12.png 18w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf.png 1536w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Mixing process of steel fiber reinforced concrete for industrial flooring<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Definition of Steel Fiber Reinforced Concrete<\/strong><\/h2>\n\n\n\n<p>According to the standard <strong>JG\/T472<\/strong>, steel fiber reinforced concrete is defined as concrete with <strong>uniformly distributed steel fibers added in appropriate amounts<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"293\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71.jpg\" alt=\"Illustration of mixing raw steel fibers with concrete to create high-performance steel fiber reinforced concrete (SFRC)\" class=\"wp-image-919\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71-300x88.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71-768x225.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71-18x5.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Steel fiber + concrete = steel fiber reinforced concrete<\/figcaption><\/figure>\n\n\n\n<p>These randomly distributed fibers help:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Prevent micro-crack development<\/li>\n\n\n\n<li>Control macro-crack formation<\/li>\n\n\n\n<li>Improve <strong>tensile strength, flexural strength, impact resistance, and fatigue performance<\/strong><\/li>\n<\/ul>\n\n\n\n<p>SFRC also offers better <strong>ductility and durability<\/strong> compared to traditional concrete.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Key Materials and Performance Requirements<\/strong><\/h2>\n\n\n\n<p>Steel fiber concrete is composed of:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Steel fibers<\/li>\n\n\n\n<li>Cement<\/li>\n\n\n\n<li>Aggregates<\/li>\n\n\n\n<li>Water<\/li>\n\n\n\n<li>Admixtures and mineral additives<\/li>\n<\/ul>\n\n\n\n<p>To ensure optimal performance:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Steel fibers must have <strong>high tensile strength and elastic modulus<\/strong><\/li>\n\n\n\n<li>The mix design should provide <strong>good workability and cohesion<\/strong><\/li>\n\n\n\n<li>Fiber distribution must be <strong>uniform<\/strong><\/li>\n<\/ul>\n\n\n\n<p>According to standards, SFRC strength grades typically range from <strong>C20 to C100<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"675\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7.jpg\" alt=\"Professional steel fiber reinforced concrete (SFRC) mix for industrial floor durability\" class=\"wp-image-920\" style=\"aspect-ratio:16\/9;object-fit:cover\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7-300x203.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7-768x518.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7-18x12.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Steel Fiber Reinforced Concrete Mix<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Construction Process of Steel Fiber Concrete Flooring<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Base Preparation<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Clean and level the base surface<\/li>\n\n\n\n<li>Remove protrusions to avoid stress concentration<\/li>\n\n\n\n<li>Install plastic film to:\n<ul class=\"wp-block-list\">\n<li>Prevent moisture loss<\/li>\n\n\n\n<li>Act as a vapor barrier<\/li>\n\n\n\n<li>Reduce base restraint and cracking risk<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a.jpg\" alt=\"Professional base preparation and soil compaction before pouring steel fiber reinforced concrete floors\" class=\"wp-image-921\" style=\"aspect-ratio:1.333344907809299;width:600px;height:auto\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\"><strong>Preparaci\u00f3n de la base<\/strong><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4.jpg\" alt=\"Laying heavy-duty plastic film moisture barrier for steel fiber reinforced concrete (SFRC) industrial flooring\" class=\"wp-image-922\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\"><strong>Laying Plastic Film<\/strong><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Isolation Joints Setup<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Set isolation joints around walls and columns<\/li>\n\n\n\n<li>Prevent edge cracking and stress concentration<\/li>\n\n\n\n<li>Install load transfer bars at construction joints<\/li>\n\n\n\n<li>Combine with <strong>armour joints<\/strong> for joint-free flooring solutions<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f.jpg\" alt=\"Installing steel dowel bars for load transfer at construction joints in steel fiber reinforced concrete (SFRC) industrial floors\" class=\"wp-image-923\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Dowel Bars Installed at Construction Joints<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Concrete Placement<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Steel fiber concrete can be poured by <strong>truck discharge or pumping<\/strong><\/li>\n\n\n\n<li>Due to reduced flowability, longer vibration time is required<\/li>\n<\/ul>\n\n\n\n<p>Recommended method:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Use <strong>laser screed machine<\/strong> for leveling<\/li>\n\n\n\n<li>Ensure no air bubbles and proper slurry formation<\/li>\n\n\n\n<li>Maintain ~2mm surface layer to prevent fiber exposure<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165.jpg\" alt=\"Professional pouring and spreading of steel fiber reinforced concrete (SFRC) for industrial floor slabs\" class=\"wp-image-924\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Concrete Pouring and Spreading<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f.jpg\" alt=\"Laser screed leveling for super flat steel fiber reinforced concrete (SFRC) industrial floor construction\" class=\"wp-image-925\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Laser Screed Leveling<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Wear-Resistant Surface Treatment<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Apply dry shake hardener during initial setting stage<\/li>\n\n\n\n<li>Ensure even distribution<\/li>\n\n\n\n<li>Use power trowel and finishing machines for polishing<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230.jpg\" alt=\"Broadcasting dry shake hardener over wet steel fiber reinforced concrete (SFRC) for extra wear resistance\" class=\"wp-image-926\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Broadcast Dry Shake Hardener<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac.jpg\" alt=\"Using a power trowel to finish the surface of a steel fiber reinforced concrete industrial floor\" class=\"wp-image-927\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Power Troweling<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb.jpg\" alt=\"Fine polishing of steel fiber reinforced concrete (SFRC) slab to achieve a high-gloss industrial finish\" class=\"wp-image-928\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fine Polishing<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>5. Curing and Joint Cutting<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cover and cure for <strong>at least 14 days<\/strong><\/li>\n\n\n\n<li>Apply curing compound to prevent moisture loss<\/li>\n\n\n\n<li>Cut expansion joints at <strong>1\/3 depth of slab thickness<\/strong><\/li>\n\n\n\n<li>Maintain moisture during cutting process<\/li>\n<\/ul>\n\n\n\n<p>Proper curing ensures maximum strength and durability.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why Choose Steel Fiber Concrete for Industrial Floors?<\/strong><\/h2>\n\n\n\n<p>Compared with Steel Fiber Reinforced Concrete vs Rebar, SFRC offers:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Superior crack resistance<\/li>\n\n\n\n<li>Mayor vida \u00fatil<\/li>\n\n\n\n<li>Reduced maintenance cost<\/li>\n\n\n\n<li>Better performance under heavy loads<\/li>\n<\/ul>\n\n\n\n<p>It is widely used in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Industrial plants<\/li>\n\n\n\n<li>Almacenes<\/li>\n\n\n\n<li>Centros log\u00edsticos<\/li>\n\n\n\n<li>Heavy-duty flooring systems<\/li>\n<\/ul>\n\n\n\n<p>Steel Fiber Reinforced Concrete can significantly improve crack resistance and durability.<br>\ud83d\udc49 Learn more about our <strong><a href=\"https:\/\/zdmflooring.com\/es\/products\/glued-hooked-end-steel-fibers\/\">Hooked End Steel Fiber<\/a><\/strong> for high-performance applications.<\/p>\n\n\n\n<p>For technical specifications and global standards on fiber reinforcement, you can refer to the <a href=\"https:\/\/www.concrete.org\/topicsinconcrete\/topicdetail.aspx?search=fiber%20reinforced%20concrete\" target=\"_blank\" rel=\"noreferrer noopener\">American Concrete Institute (ACI)<\/a> guidelines.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>\u00bfPor qu\u00e9 se agrietan los suelos tradicionales de hormig\u00f3n armado? A la hora de dise\u00f1ar suelos industriales de alto rendimiento, el debate entre el hormig\u00f3n reforzado con fibra de acero y las barras de refuerzo es crucial para garantizar la durabilidad a largo plazo. Mientras que la malla tradicional ha sido el est\u00e1ndar, el hormig\u00f3n reforzado con fibra de acero (SFRC) es ahora la opci\u00f3n superior para mejorar la resistencia a la tracci\u00f3n y evitar el agrietamiento de la superficie en la construcci\u00f3n moderna.....<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-917","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"acf":[],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}]},"featured_image_src_large":false,"author_info":{"display_name":"zhongdimei520","author_link":"https:\/\/zdmflooring.com\/es\/author\/zhongdimei520\/"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":12,"filter":"raw","cat_ID":1,"category_count":12,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/posts\/917","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/comments?post=917"}],"version-history":[{"count":1,"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/posts\/917\/revisions"}],"predecessor-version":[{"id":929,"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/posts\/917\/revisions\/929"}],"wp:attachment":[{"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/media?parent=917"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/categories?post=917"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zdmflooring.com\/es\/wp-json\/wp\/v2\/tags?post=917"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}