{"id":917,"date":"2026-03-23T08:48:16","date_gmt":"2026-03-23T08:48:16","guid":{"rendered":"https:\/\/zdmflooring.com\/?p=917"},"modified":"2026-03-23T08:48:16","modified_gmt":"2026-03-23T08:48:16","slug":"steel-fiber-reinforced-concrete-vs-rebar","status":"publish","type":"post","link":"https:\/\/zdmflooring.com\/fr\/steel-fiber-reinforced-concrete-vs-rebar\/","title":{"rendered":"Fibre d'acier ou armature traditionnelle : quel est le meilleur rapport co\u00fbt-efficacit\u00e9 ?"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>Why Does Traditional Reinforced Concrete Flooring Crack?<\/strong><\/h2>\n\n\n\n<p>When designing high-performance industrial floors, the debate of <strong>Steel Fiber Reinforced Concrete vs Rebar<\/strong> is crucial for ensuring long-term durability. While traditional mesh has been the standard, <strong>Steel Fiber Reinforced Concrete (SFRC)<\/strong> is now the superior choice to enhance tensile strength and prevent surface cracking in modern construction.<\/p>\n\n\n\n<p>In traditional concrete flooring, <strong>steel reinforcement mesh is distributed in a two-dimensional (2D) plane<\/strong>, which cannot provide effective three-dimensional restraint within the concrete structure.<\/p>\n\n\n\n<p>As a result, two major problems occur:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The upper layer of plain concrete is prone to <strong>surface peeling and spalling<\/strong><\/li>\n\n\n\n<li>Once cracks form inside the concrete, they easily <strong>propagate to the surface<\/strong> due to the lack of multi-directional reinforcement<\/li>\n<\/ul>\n\n\n\n<p>This limitation makes conventional reinforced concrete floors vulnerable to cracking, especially in <strong>industrial and heavy-load environments<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>How Steel Fiber Concrete Solves Cracking Problems<\/strong><\/h2>\n\n\n\n<p><strong>Steel fiber reinforced concrete (SFRC)<\/strong> replaces traditional rebar mesh with a <strong>three-dimensional (3D) reinforcement system<\/strong>.<\/p>\n\n\n\n<p>Instead of a flat reinforcement layer, steel fibers are <strong>evenly distributed throughout the entire concrete matrix<\/strong>, forming a spatial support structure.<\/p>\n\n\n\n<p>This provides:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Full-directional restraint against internal stress<\/li>\n\n\n\n<li>Improved tensile strength and crack resistance<\/li>\n\n\n\n<li>Better load distribution<\/li>\n<\/ul>\n\n\n\n<p>As a result:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Surface layer peeling is significantly reduced<\/li>\n\n\n\n<li>Internal cracks are effectively controlled and prevented from expanding<\/li>\n<\/ul>\n\n\n\n<p>\ud83d\udc49 In simple terms:<br><strong>Steel fibers make cracks \u201chave nowhere to go.\u201d<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-1024x683.png\" alt=\"Steel Fiber Reinforced Concrete vs Rebar Mixing process of steel fiber reinforced concrete for industrial flooring\" class=\"wp-image-918\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-1024x683.png 1024w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-300x200.png 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-768x512.png 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf-18x12.png 18w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/da240ab0-e794-4ca8-bb35-8a6964819dbf.png 1536w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Mixing process of steel fiber reinforced concrete for industrial flooring<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Definition of Steel Fiber Reinforced Concrete<\/strong><\/h2>\n\n\n\n<p>According to the standard <strong>JG\/T472<\/strong>, steel fiber reinforced concrete is defined as concrete with <strong>uniformly distributed steel fibers added in appropriate amounts<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"293\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71.jpg\" alt=\"Illustration of mixing raw steel fibers with concrete to create high-performance steel fiber reinforced concrete (SFRC)\" class=\"wp-image-919\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71-300x88.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71-768x225.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/b1ab3a152974a323a5396501dd400a71-18x5.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Steel fiber + concrete = steel fiber reinforced concrete<\/figcaption><\/figure>\n\n\n\n<p>These randomly distributed fibers help:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Prevent micro-crack development<\/li>\n\n\n\n<li>Control macro-crack formation<\/li>\n\n\n\n<li>Improve <strong>tensile strength, flexural strength, impact resistance, and fatigue performance<\/strong><\/li>\n<\/ul>\n\n\n\n<p>SFRC also offers better <strong>ductility and durability<\/strong> compared to traditional concrete.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Key Materials and Performance Requirements<\/strong><\/h2>\n\n\n\n<p>Steel fiber concrete is composed of:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Steel fibers<\/li>\n\n\n\n<li>Cement<\/li>\n\n\n\n<li>Aggregates<\/li>\n\n\n\n<li>Water<\/li>\n\n\n\n<li>Admixtures and mineral additives<\/li>\n<\/ul>\n\n\n\n<p>To ensure optimal performance:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Steel fibers must have <strong>high tensile strength and elastic modulus<\/strong><\/li>\n\n\n\n<li>The mix design should provide <strong>good workability and cohesion<\/strong><\/li>\n\n\n\n<li>Fiber distribution must be <strong>uniform<\/strong><\/li>\n<\/ul>\n\n\n\n<p>According to standards, SFRC strength grades typically range from <strong>C20 to C100<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"675\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7.jpg\" alt=\"Professional steel fiber reinforced concrete (SFRC) mix for industrial floor durability\" class=\"wp-image-920\" style=\"aspect-ratio:16\/9;object-fit:cover\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7-300x203.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7-768x518.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/97362a81f797cdf9ff3971835302cbb7-18x12.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Steel Fiber Reinforced Concrete Mix<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Construction Process of Steel Fiber Concrete Flooring<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Base Preparation<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Clean and level the base surface<\/li>\n\n\n\n<li>Remove protrusions to avoid stress concentration<\/li>\n\n\n\n<li>Install plastic film to:\n<ul class=\"wp-block-list\">\n<li>Prevent moisture loss<\/li>\n\n\n\n<li>Act as a vapor barrier<\/li>\n\n\n\n<li>Reduce base restraint and cracking risk<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a.jpg\" alt=\"Professional base preparation and soil compaction before pouring steel fiber reinforced concrete floors\" class=\"wp-image-921\" style=\"aspect-ratio:1.333344907809299;width:600px;height:auto\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/13eca355090d60c562fcb0f0bdde5d6a-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\"><strong>Pr\u00e9paration de la base<\/strong><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4.jpg\" alt=\"Laying heavy-duty plastic film moisture barrier for steel fiber reinforced concrete (SFRC) industrial flooring\" class=\"wp-image-922\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/38bda90f7dfe80d4229d2d444178bfc4-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\"><strong>Laying Plastic Film<\/strong><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Isolation Joints Setup<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Set isolation joints around walls and columns<\/li>\n\n\n\n<li>Prevent edge cracking and stress concentration<\/li>\n\n\n\n<li>Install load transfer bars at construction joints<\/li>\n\n\n\n<li>Combine with <strong>armour joints<\/strong> for joint-free flooring solutions<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f.jpg\" alt=\"Installing steel dowel bars for load transfer at construction joints in steel fiber reinforced concrete (SFRC) industrial floors\" class=\"wp-image-923\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/08a1e2c530a9d5528d7158a60d5a148f-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Dowel Bars Installed at Construction Joints<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Concrete Placement<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Steel fiber concrete can be poured by <strong>truck discharge or pumping<\/strong><\/li>\n\n\n\n<li>Due to reduced flowability, longer vibration time is required<\/li>\n<\/ul>\n\n\n\n<p>Recommended method:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Use <strong>laser screed machine<\/strong> for leveling<\/li>\n\n\n\n<li>Ensure no air bubbles and proper slurry formation<\/li>\n\n\n\n<li>Maintain ~2mm surface layer to prevent fiber exposure<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165.jpg\" alt=\"Professional pouring and spreading of steel fiber reinforced concrete (SFRC) for industrial floor slabs\" class=\"wp-image-924\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/bd58762f2ac289fccc0ac36e97962165-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Concrete Pouring and Spreading<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f.jpg\" alt=\"Laser screed leveling for super flat steel fiber reinforced concrete (SFRC) industrial floor construction\" class=\"wp-image-925\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/3e63e16d8a5a0bc50abf647461a5106f-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Laser Screed Leveling<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Wear-Resistant Surface Treatment<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Apply dry shake hardener during initial setting stage<\/li>\n\n\n\n<li>Ensure even distribution<\/li>\n\n\n\n<li>Use power trowel and finishing machines for polishing<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230.jpg\" alt=\"Broadcasting dry shake hardener over wet steel fiber reinforced concrete (SFRC) for extra wear resistance\" class=\"wp-image-926\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/6ab7e484d027fde0628789c84e249230-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Broadcast Dry Shake Hardener<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac.jpg\" alt=\"Using a power trowel to finish the surface of a steel fiber reinforced concrete industrial floor\" class=\"wp-image-927\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/78cb37e87edb6b4cc9e43d586bf79cac-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Power Troweling<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb.jpg\" alt=\"Fine polishing of steel fiber reinforced concrete (SFRC) slab to achieve a high-gloss industrial finish\" class=\"wp-image-928\" style=\"width:600px\" title=\"\" srcset=\"https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb.jpg 1000w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb-300x225.jpg 300w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb-768x576.jpg 768w, https:\/\/zdmflooring.com\/wp-content\/uploads\/2026\/03\/40533394229f45f763f8813c85d405cb-16x12.jpg 16w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fine Polishing<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>5. Curing and Joint Cutting<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cover and cure for <strong>at least 14 days<\/strong><\/li>\n\n\n\n<li>Apply curing compound to prevent moisture loss<\/li>\n\n\n\n<li>Cut expansion joints at <strong>1\/3 depth of slab thickness<\/strong><\/li>\n\n\n\n<li>Maintain moisture during cutting process<\/li>\n<\/ul>\n\n\n\n<p>Proper curing ensures maximum strength and durability.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why Choose Steel Fiber Concrete for Industrial Floors?<\/strong><\/h2>\n\n\n\n<p>Compared with Steel Fiber Reinforced Concrete vs Rebar, SFRC offers:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Superior crack resistance<\/li>\n\n\n\n<li>Dur\u00e9e de vie plus longue<\/li>\n\n\n\n<li>Reduced maintenance cost<\/li>\n\n\n\n<li>Better performance under heavy loads<\/li>\n<\/ul>\n\n\n\n<p>It is widely used in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Industrial plants<\/li>\n\n\n\n<li>Warehouses<\/li>\n\n\n\n<li>Logistics centers<\/li>\n\n\n\n<li>Heavy-duty flooring systems<\/li>\n<\/ul>\n\n\n\n<p>Steel Fiber Reinforced Concrete can significantly improve crack resistance and durability.<br>\ud83d\udc49 Learn more about our <strong><a href=\"https:\/\/zdmflooring.com\/fr\/products\/glued-hooked-end-steel-fibers\/\">Hooked End Steel Fiber<\/a><\/strong> for high-performance applications.<\/p>\n\n\n\n<p>For technical specifications and global standards on fiber reinforcement, you can refer to the <a href=\"https:\/\/www.concrete.org\/topicsinconcrete\/topicdetail.aspx?search=fiber%20reinforced%20concrete\" target=\"_blank\" rel=\"noreferrer noopener\">American Concrete Institute (ACI)<\/a> guidelines.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Pourquoi les planchers traditionnels en b\u00e9ton arm\u00e9 se fissurent-ils ? Lors de la conception de sols industriels de haute performance, le d\u00e9bat entre le b\u00e9ton arm\u00e9 de fibres d'acier et les barres d'armature est crucial pour assurer la durabilit\u00e9 \u00e0 long terme. Alors que le treillis traditionnel a \u00e9t\u00e9 la norme, le b\u00e9ton renforc\u00e9 de fibres d'acier (SFRC) est d\u00e9sormais le meilleur choix pour am\u00e9liorer la r\u00e9sistance \u00e0 la traction et pr\u00e9venir la fissuration de la surface dans les constructions modernes.....<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-917","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"acf":[],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}]},"featured_image_src_large":false,"author_info":{"display_name":"zhongdimei520","author_link":"https:\/\/zdmflooring.com\/fr\/author\/zhongdimei520\/"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":12,"filter":"raw","cat_ID":1,"category_count":12,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/posts\/917","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/comments?post=917"}],"version-history":[{"count":1,"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/posts\/917\/revisions"}],"predecessor-version":[{"id":929,"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/posts\/917\/revisions\/929"}],"wp:attachment":[{"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/media?parent=917"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/categories?post=917"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zdmflooring.com\/fr\/wp-json\/wp\/v2\/tags?post=917"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}